Intel® Graphics Media Accelerator
Production Version 15.12.75.50.2.2023
Release Notes
December
17, 2009
Microsoft
Windows* 7
INTEL CONFIDENTIAL
INFORMATION IN THIS DOCUMENT IS PROVIDED
IN CONNECTION WITH INTEL PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL
OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS
DOCUMENT. EXCEPT AS PROVIDED IN INTEL'S TERMS AND CONDITIONS OF SALE FOR
SUCH PRODUCTS, INTEL ASSUMES NO LIABILITY WHATSOEVER AND INTEL DISCLAIMS ANY
EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF INTEL PRODUCTS
INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE,
MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL
PROPERTY RIGHT.
UNLESS OTHERWISE AGREED IN WRITING BY INTEL, THE INTEL PRODUCTS ARE NOT
DESIGNED NOR INTENDED FOR ANY APPLICATION IN WHICH THE FAILURE OF THE INTEL
PRODUCT COULD CREATE A SITUATION WHERE PERSONAL INJURY OR DEATH MAY OCCUR.
Intel may make changes to specifications and product descriptions at any time,
without notice. Designers must not rely on the absence or characteristics of
any features or instructions marked "reserved" or
"undefined." Intel reserves these for future definition and shall
have no responsibility whatsoever for conflicts or incompatibilities arising
from future changes to them. The information here is subject to change without
notice. Do not finalize a design with this information.
The products described in this document may contain design defects or errors
known as errata, which may cause the product to deviate from published
specifications. Current characterized errata are available on request.
Contact your local Intel sales office or your distributor to obtain the latest
specifications and before placing your product order.
*Other names and brands may be claimed as the property of
others.
Copyright © 2009, Intel Corporation. All rights reserved.
|
Date |
Driver Revision |
Description |
Build Number |
|
December 17,
2009 |
Production
Version 15.12.75.50.2.2023 |
Production
Version; fully Validated |
2023 |
|
October 21,
2009 |
Production
Version 15.12.75.50.1.1972 |
Production
Version; fully Validated |
1972 |
|
October 05, 2009 |
Production
Version 15.12.75.50.1929 |
Production
Version; fully Validated |
1929 |
|
August 05,
2009 |
Beta
15.12.75.50.1862 |
Weekly
engineering drop; not fully validated |
1862 |
|
July 28, 2009 |
Alpha
15.12.75.50.1849 |
Weekly engineering
drop; not fully validated |
1849 |
|
July 22, 2009 |
Beta
15.12.75.50.1849 |
Weekly
engineering drop; not fully validated |
1849 |
|
July 08, 2009 |
Alpha
15.12.75.50.1837 |
Weekly
engineering drop; not fully validated |
1837 |
Intel® Graphics Media Accelerator Driver
The Intel® Graphics Media Accelerator Driver contains support for the following Intel Chipsets:
· Pineview Desktop Express Chipset Family
· Pineview Mobile Express Chipset Family
New Features
|
Reference No. |
Description |
Affected
Components |
Build |
|
1022963 |
LVDS Adaptive Clocking for Pineview |
SoftBIOS |
2023 |
Known Issues
|
Known Issues in Build 2023 |
||||
|
Reference No. |
Description |
Affected
Component(s) |
Affected OS(s) |
Affected Project(s) |
|
3290112 |
VBIOS version in CUI information page shows with .(dot) zero extension. |
CUI |
Windows* 7 |
Pineview Mobile |
|
3038235 (partially fixed) |
GFX-UI-ENU-Windows Display Properties menu-Advanced Settings: the Intel Banner does not stretch across the top of the frame like it should. |
Loc Translation |
Windows* 7 |
Pineview Mobile |
|
3174808 |
The LFP backlight remains unchanged (maximum) when the
power plan slider bar in OS set to minimum for both AC and DC. |
Power Conservation |
Windows* 7 |
Pineview Mobile |
|
3176277 |
Momentary corruption seen over the top edge of screen
when booting to Win7 OS |
GMM |
Windows* 7 |
Pineview Mobile |
Issues Resolved
|
Issues Resolved in Build 2023 |
|||||||||||
|
Reference No. |
Description |
Affected Component(s) |
Affected OS(s) |
Affected Project(s) |
|||||||
|
Bug ID: 3291544 |
Version number mismatch
in CUI information page and device manager page. |
INF File |
Windows* 7 |
Pineview Desktop |
|||||||
|
Root Cause: CUI is getting driver version
from driver which is 7.15.10.xxxx but device manger is getting this data from
INF where it is 7.14.10.xxxx. Fix: This issue has been
fixed in the INF file. |
|||||||||||
|
Bug ID:
3291902 |
Adding a movie clip
into Powerpoint, BSOD occurs. |
GMM |
Windows* 7 |
Pineview Mobile |
|||||||
|
Root Cause: When Overlay is on, the
driver updated the fence register which was being used by the overlay and
this causes the Overlay request to stall and subsequent hang. Fix: This issue has been
fixed in the GMM component. |
|||||||||||
|
Bug ID:
3291648 |
The "Maintain
Aspect Ratio" is no function on Win 7 |
NT-Miniport |
Windows* 7 |
Pineview Mobile |
|||||||
|
Root Cause: When we select maintain
aspect scaling, then driver is properly giving the scaling option and also
CUI is sending right scaling option to OS to set display settings. But OS is
not giving a commit call. OS is driving Maintain aspect scaling and is
thinking there is no change in settings and so not driving the change display
settings. Fix: PNV graphics driver for
Win7 is WDDM 1.0 architecture, so driver doesn’t understands MAR [OS
limitation due to lack of CCD support], so a workaround has been implemented
in the driver which fixes this issue. |
|||||||||||
|
Bug ID:
3176808 |
There is bright line on
top of panel when resuming from S3/S4. Also: Logon display several stripes when log on windows
desktop. |
CUI |
Windows* 7 |
Pineview Mobile |
|||||||
|
Root Cause: OS and CUI set Display
gamma color values simultaneously due to which there is white line observed. Fix: Issue was fixed by
introducing a delay. |
|||||||||||
|
Bug ID:
3292086 |
Playing KartRider
online game observe display blinking. Also: Screen is blinking for a moment during playing
Maplestory game. |
SoftBIOS |
Windows* 7 |
Pineview Mobile |
|||||||
|
Root Cause: Incorrect framecount
was being sent to the OS which was causing this issue. Fix: Issue was fixed in the SoftBIOS
component of the driver. |
|||||||||||
|
Bug ID:
3290662 |
SG interface exposed on
Pineview |
NT-Miniport |
Windows* 7 |
Pineview Desktop |
|||||||
|
Root Cause: Switchable Graphics interfaces
are exposed with PineView branch drivers. Switchable Graphics is not
supported on PNV, so interfaces need to be removed or hidden. Fix: SG support has been
removed from NT-miniport component which fixes this issue. |
|||||||||||
|
Issues Resolved in Build 1972 |
|||||||||||
|
Reference No. |
Description |
Affected Component(s) |
Affected OS(s) |
Affected Project(s) |
|||||||
|
Bug ID: Internal |
Black screen may occur during VGA hot plug with certain
monitors |
Driver and VBIOS |
Windows* 7 |
Pineview Desktop |
|||||||
|
Root Cause: Issue occurs when not all channels of R,G and B are terminated properly
on the monitor or there is a loose connection, the system reacts to it by displaying
black image. This has been root caused as a bug in both VBIOS as well as the
graphics driver. For more details, please refer to doc :
“GMA3150__Black_Screen_Alert_WW43.pdf” Fix: This issue has been fixed in the driver and the VBIOS. For the problem to
be completely solved, upgrading of driver as well as VBIOS is required. |
|||||||||||
|
Issues Resolved in Build 1929 |
|||||||||||
|
Reference No. |
Description |
Affected Component(s) |
Affected OS(s) |
Affected Project(s) |
|||||||
|
Bug ID: 3175783 |
The brightness is still 19 levels on Win7 driver |
Power Conservation |
Windows* 7 |
Pineview Mobile |
|||||||
|
Root Cause: Win7 recommends a minimum of 25 backlight brightness levels. OpRegion BCLM
was not extrapolating between the next lower level and higher level for 25
levels. Fix: In BCLM table of Power Conservation component , new brightness duty cycle
values were generated that fixes this issue. |
|||||||||||
|
Bug ID: 3177182 |
BSOD is not seen in DDC mode & SD CRT on simulating Blue Screen on
Win7 OS |
VBIOS |
Windows* 7 |
Pineview Desktop |
|||||||
|
Root Cause: CRT hot plug status bit was getting set even though CRT was connected. Fix: This issue was fixed in the VBIOS. |
|||||||||||
|
Bug ID: 3177184 |
Not able to apply 656* 496 resolution in DDC mode WIN 7 |
SoftBIOS |
Windows* 7 |
Pineview Desktop |
|||||||
|
Root Cause: This is because with latest Win7 build (7600) OS is pruning this mode.
Driver is adding this mode in CRT modelist and reporting to OS. But once it
is applied, OS does not allow it to set this mode. Fix: CUI was modified to be in sync when Hide Mode box is checked. |
|||||||||||
|
Bug ID: 3174808 |
The LFP backlight remains unchanged (maximum) when the power plan slider
bar in OS set to minimum for both AC and DC. |
Power Conservation |
Windows* 7 |
Pineview Mobile |
|||||||
|
Root Cause: Needed to add support for OS API for BLC control Fix: Support was added to BLCControl APIs which fixed this issue. |
|||||||||||
|
Bug ID: 3176122 |
Driver version is different between inf file and igfxpph.dll |
CUI |
Windows* 7 |
Pineview Desktop |
|||||||
|
Root Cause: CUI binaries were not in
sync with inf and driver binaries. Fix: Version information was
updated in the version setup file of CUI, which fixed the issue. |
|||||||||||
|
Issues Resolved in Build 1862 |
|||||||||||
|
Reference No. |
Description |
Affected Component(s) |
Affected OS(s) |
Affected Project(s) |
|||||||
|
Bug ID: 3040098 |
Not able to apply the Downscaled modes (10x7 & 11x8) on
WIN7 using CUI |
NT-Miniport |
Windows* 7 |
Pineview Desktop |
|||||||
|
Root Cause: In the driver, we have a check for Native resolution of the
panel (Mode in EDID), which causes this function call to fail for to-be
downscaled modes. Fix: Whenever call comes for modes greater than Native, driver
will handle it appropriately if Downscaler is enabled. |
|||||||||||
|
Bug ID: 3506351 |
Left-shifted display on secondary monitor |
SoftBIOS |
Windows* 7 |
Pineview Desktop |
|||||||
|
Root Cause: CRT display clock was not being
programmed as per the PLL sheet for modes less than 1280x1024. Fix: Driver code has been
updated, so that CRT display clock is in unison with DPLL Clock Sheet. |
|||||||||||
|
Bug ID: 3174631 |
BSOD occurs when rotating independent display devices. |
KMD Render |
Windows* 7 |
Pineview Desktop |
|||||||
|
Root Cause: When Independent rotation is enabled and when executing the
MMIO flip function where-in the function to save and restore floating point state
is called, this issue occurs. Fix: A workaround has been implemented to avoid this call, and
this fixes the issue. |
|||||||||||
|
RCR ID: 1022951 |
TV/ CRT static feature (forced detection) removal from
Windows7 drivers. |
CUI |
Windows* 7 |
Pineview Desktop |
|||||||
|
Requirement: The option to force detect CRT/ TV is provided by the OS on
Windows7. This feature was provided by the Gfx driver on earlier OS - Vista,
XP. Since it is provided by the Win7 OS now, it negates the requirement for
the driver to provide the same and has been removed. |
|||||||||||
|
Issues Resolved in Build 1849 |
|||||||||||
|
Reference No. |
Description |
Affected Component(s) |
Affected OS(s) |
Affected Project(s) |
|||||||
|
Bug ID: 3040040 |
BSOD observed after running TDR app. |
NT-Miniport |
Windows* 7 |
Pineview Desktop |
|||||||
|
Root Cause: Driver was not gracefully handling the GPU reset when the TDR
app was run. This was because wrong register definition was used for PNV. Fix: This has been fixed in Miniport component. |
|||||||||||
|
Issues Resolved in Build 1837 – None for this build |
|||||||||||
|
Reference No. |
Description |
Affected Component(s) |
Affected OS(s) |
Affected Project(s) |
|||||||
|
Bug ID: |
|
|
|
|
|||||||
|
Root Cause: |
|||||||||||